ADEMCO VISTA-250FBP Setup Guide Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 136
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
VISTA-128FBP/VISTA-250FBP Installation and Setup Guide
3-18
INPUT POLLING LOOP
CONTROL PANEL
EXTENSION POLLING LOOP #1
4297
COMBINED INPUT AND EXTENSION LOOP LIMITS:
NO MORE THAN 119 DEVICES COMBINED ON THE INPUT LOOP AND EXTENSION LOOP #1. NO MORE THAN 119 DEVICES COMBINED
ON THE INPUT LOOP AND EXTENSION LOOP #2.
TOTAL LENGTH OF ALL WIRE RUNS ON THE INPUT LOOP AND EXTENSION LOOP #1 COMBINED CANNOT EXCEED 6400 FT. (3200 FT.
IF USING UNSHIELDED WIRE IN CONDUIT, OR SHIELDED WIRE). TOTAL LENGTH OF ALL WIRE RUNS ON THE INPUT LOOP AND EX-
TENSION LOOP #2 COMBINED CANNOT EXCEED 6400 FT. (3200 FT. IF USING UNSHIELDED WIRE IN CONDUIT, OR SHIELDED WIRE).
WHEN USING THE 4297 TO EXTEND THE POLLING LOOPS, FIRE DEVICES MUST BE ON SEPARATE LOOPS FROM BURG DEVICES TO
PROVIDE ISOLATION.
4297
DO NOT CONNECT 4297 MODULES IN
SERIES (i.e., DO NOT CONNECT ONE
MODULE'S EXTENSION LOOP TO
ANOTHER MODULE'S INPUT LOOP.)
polling_loop-013-V1
TO
BURG
DEVICES
TO
FIRE
DEVICES
EXTENSION POLLING LOOP #2
CLASS B, STYLE 3
CLASS B, STYLE 3
V-PLEX
DEVICE
V-PLEX
DEVICE
2 1
6
7
8
9
2 1
6
7
8
9
TO PANEL AUX POWER
TO PANEL AUX POWER
DO NOT CONNECT
Figure 3-17: Polling Loop Connections Using Multiple Extender Modules
NOTE: The input loop limits stated in Figure 3-16 apply to Figure 3-17 as well.
Wireless Zone Expansion
U
L
The 5881ENHC RF Receiver is Listed for Commercial Fire and Commercial Burglary applications. The 5883H is
Listed for Commercial Fire applications only. All other RF receivers are not UL listed for Commercial applications.
The following table lists the receivers that may be used and the number of zones they support.
5800 Series Receivers
Receiver Zones
5881ENHC up to 250 (use in commercial fire or
burglary applications)
5883H up to 250 (use in commercial fire
applications)
RF System Operation and Supervision
The 5800 RF system operation has the following characteristics:
The receiver responds to a frequency of 345MHz.
The receiver has a nominal range of 200 feet.
Supervised transmitters send a supervisory signal every 70-90 minutes.
Zones 988 and 990 are used to supervise the RF reception of receivers 2 and 1, respectively. The reception is
supervised for the following two conditions:
1. The receiver goes “deaf” (doesn’t hear from any transmitter) within a programmed interval of time (defined by
program field 1*30).
2. Proper RF reception is impeded (i.e., jamming or other RF interference). The control checks for this condition
every 20 seconds.
Page view 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 135 136

Comments to this Manuals

No comments