U
L
A UL Listed keyswitch is required for fire
installations and UL commercial and residential burglar
alarm installations.
If a keyswitch is used on:
an installation that transmits opening and closing
signals, the keyswitch zone must be programmed to
send opening and closing signals.
a UL commercial burglar alarm installation, the
keyswitch’s tamper switch must be connected in to
the alarm system. This tamper switch zone must
also be programmed for Zone Type 05 – Trouble by
Day / Alarm by Night.
a fire alarm installation, the keyswitch must be
located next to an alphanumeric display keypad.
The Ademco 4146 keyswitch is UL Listed.
4146 KEYSWITCH
(READY)
GREEN
LOCK
SWITCH (N. O.)
TAMPER
SWITCH (N. C.)
(ARMED)
RED
YELLOW
WHITE
EOLR
(use appropriate value)
11
10
TYPICAL ZONE
ON CONTROL
BOARD
BROWN
BLUE
BROWN
BLUE
820
ohms
820
ohms
00-trigcon-004-V3
1345
4-WIRE
CABLE
5-PIN TRIGGER CONNECTOR
KEY
+12 AUX.
OUTPUT 17
OUTPUT 18
(RED)
(YELLOW)
(GREEN)
RED
BLACK
Figure 10. Keyswitch Wiring Connections
Connecting Relay Modules
1. Mount either remotely or in the control panel.
2. Connect to control’s keypad terminals using the connector harness supplied with the module. Use
standard 4-conductor twisted cable for long wiring runs.
3. Set the module’s device address to address 12.
4. Connect the desired field wiring to the unit's relay contact terminals.
NOTES
Use 4204 module.
Supervision: 4204 module is supervised against removal. The module’s device address is displayed
as follows if a module is disconnected from the control’s terminals, or if the module cover is removed
and the tamper jumper is installed:
Alpha: CHECK xx Wire Expansion
FAULT xx Wire Expansion
ALARM xx Wire Expansion
Fixed-Glass: lxx (or 91 if field *199 set for 2-digit display); where “xx is the module’s address.
If communication/tamper failure occurs on a device with zones wired to it, all zones on the device
will be displayed.
U
L
For UL installation requirements, refer to the
Installation Instructions for the 4204.
TB2
121110
9
87654321
() GROUND
(+) 12V
YEL
BLK
GRN
RED
13 14 15 16
DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER
COVER TAMPER (REED) SWITCH
TB1
4204
4-PIN TOUCHPAD PLUG
3
2
RELAY
1
4
TYPICAL
(SHOWN "OFF")
C
NC
NO
C
NC
NO
C
NC
4204_conn-1-V0
NC
NO
C
NC
NO
EITHER OR BOTH
CAN BE USED
DATA IN
FROM CONTROL
DATA OUT
TO CONTROL
RELAY
RELAY
RELAY
Figure 11. 4204 Connections to Control
Mounting and Wiring the Control
2-9
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 71 72

Comments to this Manuals

No comments

InSinkErator SS-50 podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Ekwipunek InSinkErator SS-50.
Dostarczamy 1 pdf podręczników InSinkErator SS-50 do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika






Więcej produktów i instrukcji dla Ekwipunek InSinkErator

Modele Rodzaj dokumentu
LC-50 Instrukcja Użytkownika   InSinkErator LC-50 User Manual, 13 strony
WX-300 Instrukcja Użytkownika   InSinkErator WX-300 User Manual, 30 strony
F-C1100 Cold Only Faucet Instrukcja Użytkownika     InSinkErator F-C1100 Cold Only Faucet User Manual, 20 strony