Audio Alarm Verification Connections (AAV, “listen-In”)
Refer to the connection diagrams below. One diagram shows connections when a 4285/4286 Phone
Module is used, the other shows connections when the 4285/4286 is not used.
Connections use one of the on-board triggers.
U
L
UL installations using the AAV feature must use the ADEMCO UVCM module (part of the ADEMCO UVS
system)
Suggested AAV Module: ADEMCO UVS (shown) or Eagle 1250
NOTES
Set field *91 for AAV and program the appropriate output (output 17 or 18) using *80 Menu mode:
select zone type 60 and output action 1 (close for 2 seconds) or action 2 (stay closed).
For voice session monitoring, connect a zone to UVCM module terminals 6 & 7, and program the
zone as zone type 81 (*56 Menu mode).
E.g.,
Using output 18 for the trigger, program an output function in *80 Menu mode as:
ZT = 60, P = 0, Action = 1, Device = 18
ON ON
12345678 1 2345678
1234567891011
29 30 31 32 33 34
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
UVCM
MODULE
ZONE
TERMINALS
EARTH
GROUND
RED (R)
GREEN (T)
GREY (R)
BROWN (T)
TRIGGER
CONNECTOR
OUTPUT 18
EOL
RING
TIP
OPTIONAL
MONITORING ZONE
CONNECTION
(USE ZONE TYPE 81)
FALLING VOICE TRIG
GND
+12VDC IN
SWITCH
BANK 2
SWITCH
BANK 1
SWITCH BANK 2
SWITCH BANK 1
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
aav_uvcm-003-V0
CONTROL
INCOMING
PHONE LINE
TO
PREMISES
HANDSET
5
1 = ON
2 = ON
3 = OFF
4 = ON
5 = ON
6 = ON
7 = ON
8 = ON
1 = OFF
2 = OFF
3 = OFF
4 = OFF
5 = OFF
6 = OFF
7 = OFF
8 = ON
23
24
25
+12VDC
GND
4
5
21
22
RJ31X
Figure 14. Connection of AAV Unit When Not Using a 4285/4286 Phone Module
1234567891011
29 30 31 32 33 34
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
UVCM
MODULE
CONTROL
EARTH
GROUND
RED (R)
GREEN (T)
GREY (R)
BROWN (T)
TRIGGER
CONNECTOR
OUTPUT 18
4285/4286
RING
TIP
FALLING VOICE TRIG
GND
+12VDC IN
SWITCH
BANK 2
SWITCH
BANK 1
SWITCH BANK 2
SWITCH BANK 1
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
aav_uvcm-004-V0
ZONE
TERMINALS
OPTIONAL
MONITORING
ZONE
CONNECTION
(USE ZONE
TYPE 81)
23 24
25
22
21
4
5
INCOMING
PHONE LINE
TO
PREMISES
HANDSET
RJ31X
2
3
4
1
5
1 = ON
2 = ON
3 = OFF
4 = ON
5 = ON
6 = ON
7 = ON
8 = ON
1 = OFF
2 = OFF
3 = OFF
4 = OFF
5 = OFF
6 = OFF
7 = OFF
8 = ON
ON ON
12345678 1 2345678
RING
TIP
+12VDC
GND
EOL
Figure 15. Connection of AAV Unit When Using a 4285 or 4286 Phone Module
Installation Instructions
2-12