ADEMCO VISTA 10 Setup Guide Page 41

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 40
INPUT S/N L
AXXX-XXXX
Manually enter the serial number printed on the label for the wireless key or press and
release the button to transmit its serial number.
Press [] to accept the serial number. The system will check for duplicate.
If necessary, press the [#] key to back up without saving, and re-enter the serial number.
Use the [A] key to move forward within the screen, and the [B] key to move backward.
XMIT TO CONFIRM
PRESS TO SKIP
If “Yes” was entered at the SET TO CONFIRM? prompt (first prompt following entry into
the 58 Expert Programming Mode), this display appears.
Confirm serial and loop numbers by activating the wireless key. Refer to the “Confirm
prompt described in *56 Menu mode above for more information on confirming the serial
number.
If the serial number transmitted matches the serial number entered, the keypad will beep 3
times and will return you to the ENTER START ZONE NUMBER prompt to enter the
starting zone for the next wireless key.
Or you can return to *58 Menu mode by pressing 00 at the Zone Number prompt.
IMPORTANT: When confirmed, the key is not active for arming/disarming until it is
assigned to a user number (using the assigning attributes command, attribute “4”). See
System Operation section.
[] to skip confirm.
Wireless Key Predefined Default Templates
YOU MUST
PROGRAM
THIS BUTTON
LOOP 4
LOOP 3
ENROLL AS "BR"
LOOP 1
LOOP 2
ON
OFF
5804-001-V1
5804 Wireless Key Transmitter
Note:
These transmitters
are not intended for
use in UL
installations.
LOOP 3
LOOP 1
LOOP 2
LOOP 4
(YOU MUST
PROGRAM
THIS BUTTON)
RED/YELLOW
LED
GREEN/YELLOW
LED
ENROLL AS "BR"
5804BD-007-V0
5804BD 2-Way Wireless Key Transmitter
For 5804
For 5804BD
TEMPLATE 1 Loop Function Zone Type TEMPLATE 4 Loop Function Zone Type
1 No Response 23 1 No Response 23
2 Disarm 22 2 No Response 23
3 Arm Away 21 3 Arm Away 21
4 No Response 23 4 Disarm 22
TEMPLATE 2 Loop Function Zone Type TEMPLATE 5 Loop Function Zone Type
1 No Response 23 1 No Response 23
2 Disarm 22 2 Arm Stay 20
3 Arm Away 21 3 Arm Away 21
4 Arm Stay 20 4 Disarm 22
TEMPLATE 3 Loop Function Zone Type TEMPLATE 6 Loop Function Zone Type
1 24-hour audible 7 1 24-hour audible 7
2 Disarm 22 2 Arm Stay 20
3 Arm Away 21 3 Arm Away 21
4 Arm Stay 20 4 Disarm 22
5-5
Page view 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 71 72