3. If the number of digits that you need to enter in a data field is less than
the maximum digits available (for example, the phone number field), enter
the desired data, then press * and the next data field number to be
programmed.
4. If you try to enter a non-existent field, the keypad will display EE or Q
Entry Error. Simply re-enter [*] plus a valid field number.
Reviewing a Data Field/Erasing an Entry in a Data Field
Press[#] plus Field No. Data will be displayed for that field number. No
changes will be accepted in this mode.
To delete an entry in a field, press [*] plus Field No. + [*I. (Applies only to
fields *40–*46, and *94).
Interactive Mode Programming
(*56, *SO, *S1, and *82)
Typicalpromptdisplayed
Press [*] plus interactive mode No. (for example, *56). The Alpha keypad
during interactivemode
will display the first of a series of prompts requesting entries.
programming
A detailed procedure (with displays of prompts) is provided in those sections
Enter Zn Num.
1
where programming in the interactive mode is to be performed.
(00 = Quit)
01
1
Interactive Mode
Used To Program
Zone Number~
*56 Zone Programming Zone characteristics, report codes, alpha
descriptors and serial numbers
*8O Relay Programming
4229 or 4204 Relay modules, or Powerline
Carrier devices
*81 Zone List Programming
Zone Lists for relaylpowerline carrier activation
*82 Alpha Programming Zone alpha descriptors
Loading Factory Defaults
To load the factory defaults, enter the programming mode, press *97, then
exit the programming mode.
*96 resets the Subscriber Account number and CSID in preparation for an
initial download.
PrOgramnu
‘ng System Setup ~~elds
The following program fields must be programmed before doing any zone
programming.
*2S -D ZONE EXPANSION
u
Use this field to select the type of expansion unit being used, as follows:
O= none; 1 = 4219; 2 = 4229; 3 = 4204. Default is O.
*3o KEYSWITCH ENABLE
u
This field must be enabled (enter 1) if using a keyswitch. The keyswitch
must be connected to zone 7, which can then not be used for any other
purpose.
Default is O (no keyswitch).
Note: If keyswitch is enabled, in menu mode *56 the Zone Type (ZT) for
zone 7 will show “77”, and will not be accessible for programming.
Exiting the Programming
g Mode
*99 allowsre-entry~to the progr~ mode using
Installer Code + 8 0 0.
W8 mbits re-entryintothe programming mode using the Installer code.
-20-