Sounder Connections
The VISTA-20HW provides a 12 VDC output which can power external alarm
sounders (bells or sirens, see compatible sounders listed previously). This
output will activate a sounder when an alarm occurs in partition 1 or 2.
Make connections to alarm output terminals 3 (+) and 4 (-). See diagram
below.
Non-UL
hMttdkttiOllS
The total current drawn from this output cannot exceed 2 amps. A battery
must be installed since this current is supplied by the battery.
CONTROL BOARD
No. 702
SIREN
+
OUTPUT
Programming
Figure 15. Typical Sounder Wtig
for External Sounders
1.
2.
3.
4.
5.
6.
7.
With at least one 2-line Alpha keypad (5137AD or 6139) connected to the
Partition 1 keypad terminals on the control, power up the system
temporarily. If you had previously comected the AC transformer to the
control panel, you need only plug in the transformer (to 120VAC outlet) to
power up the system.
Enter the programming mode by keying the following on the Alpha
keypad Installer code
(41 12) + 8 0 0.
Press %2. (Single Alarm Sounding per Zone/Armed Period).
Enter “1” for yes, “O”for no (default). Enter “O”for UL installations.
I
Press =3. (Fire
Sounder Timeout).
Enter “1” for no timeout, “O”for timeout (default).
Press *4. (Alarm Bell Timeout).
Enter Ofor no timeout, 1 for 4 min (default), 2 for 8 rein, or 3 for 12 min.
Enter “1” for UL installations.
I
Press
=7. (Confirmation of Arming Ding).
m
There are separate entries in this field for partition 1 and for partition 2.
Enter “O” for no (default), “1” for yes.
Exit the programming mode by entering *99.