Security Codes
w
Installer Code
The installer programs the 4-digit Installer Code initially as part of the
programming procedure. The factory default Installer code is “4-l-l-2”, but
may be changed in field *20.
The Installer code is the only code that can enter programming mode and
also, in normal operation mode, is used to enter the Master code for each
partition, which allows access to the normal fimctions of the system.
See Section 4. MECHANIC’S OF PROGRAMMING for information on exiting
the programming mode via fields *98 or *99.
Master Code
In normal operation mode, the Installer code is used to enter the 4-digit
Master security code for each partition, using the keypad connected to
Partition 1:
To enter the Master code for Partition 1, enter:
Installer Code + [8] + [01] + desired 4-digit Master code for Partition 1
To enter the Master code for Partition 2, enter:
1
Installer Code + [8] + [02] + desired 4-digit Master code for Partition 2
Secondary User Codes
In normal operation mode, each partition’sMaster securitycode can be
used to assign up to 14 secondary 4-digit security codes for that partition. It
can also be used to remove secondary codes from the system (individually).
To assign (or change) a Secondaqy security code, enter (via partition’s ,
keypad):
Partition’s Master Code + [CODE key]+ User # (03-16)
+ desired Secondary Code
I
Notes:
The system will emit a single beep when each secondary code has been suc-
cessfully entered.
To delete a Secondary security code, enter (via partition’s keypad):
Partition’s Master Code + [CODE key]+ User # (03-16)
All Master and Secondary security codes permit access to the system for
arming, disarming, etc,
The installer code can disarm the system only ifit was used to arm it.
User code No. 15 is a “babysitter” code, i.e., it can disarm the system only
if it was used to arm it.
User code No. 16 is the Duress code. When this is used to perform any
system operation, a special code is sent to the monitoring station. Instruct
users to be carefi-dnot to use this code for normal usage,
If a secondary code is inadvertently repeated for different users, the lower
user number will take priority.
Opening and closing reports are sent for the Installer code as No. 01, with
the appropriate subscriber number. Each Master code and set of secondary
user codes are sent as Nos. 02, and 03–16 respectively in Contact ID
format (with the appropriate subscriber number); in 4+2, it is l–F, “F” for
anything greater than 15; keyswitch will report as user “O”.