General Information Notethat if you enabled QUICK ARM for the partition (field *21), the [#] key
can be pressed instead of entering the partition’s security code, for any of the
arming procedures (Away, Stay, Instant, Maximum, etc.). The security code is
always required, however, when disarming the system.
The keypad allows the user to arm and disarm the system, and perform other
system functions, such as bypassing zones, and display zone descriptors. Zone
and system conditions (alarm, trouble, bypass) are displayed in the Display
Window.
When an alarm occurs, keypad sounding and external sounding will occur,
and the zone(s) in alarm will be displayed on the keypad. Pressing any key
will silence the keypad sounder for 10 seconds. Disarming the system will
silence both keypad and external sounders. When the system is disarmed,
any zones that were in an alarm condition during the armed period will be
displayed (memory of alarm). To clear this display, simply repeat the disarm
sequence (enter the security code snd press the OFF key) again.
The keypads also feature chime annunciation, and 3 panic key pairs, or
individualpanickeys(dependingonkeypadtype seePanic Keys), forsilent,
audible,fireorpersonalemergencyalarms. Thesekeyscannoti~ the central
stationofan alarmcondition,if that serviceis comected.
Arming Functions The followingis a brief list of system commands. For detailedinformation
concerningsystemiimctions,referto the User’s Manual.
Disarmed, Not Ready .....Before arming, the system must be in the
READY condition(all zonesmust be intact).If
the “NOT READY’ message appears, pressthe
READY [*] keyto displayfaultedzones.
Arming Away ...................... Entercode+ AWAY [2].
Arming Stay ........................ Entercode + STAY [3].
Arming Instant ..................Enter code + INSTANT [7].
Arming Maximum ............. Enter code + MAXIMUM [4].
Disarming ........................... Enter code + OFF [1].
Bypassing Zones ................Enter code + BYPASS [6]+ zone number(s).
Forced (Quick) Bypass .....
(If enabled) To automatically bypass all faulted
zones,
use the “Quick Bypass” method:
Enter code + BYPASS, then wait for all open
zones to be displayed. Arm when display
indicates “bypass” and “ready to arm”.
Chime Mode ........................ Entercode+ CHIME [9].
Toturnchimeoff,entercode+ CHIME again.
SUMMARY OF ARMING MODES
Features for Each Arming Mode
Arming
Exit
Entry
Perimeter Interior
Mode
Delay
Delay Armed
Armed
AWAY
Yes
Yes
Yes
Yes
STAY
Yes Yes
Yes
No
I INSTANT I
Yes
I
No I Yes I
No
I
[-MAXIMUM i
Yes I No
I Yes I
Yes I
-65-