ADEMCO Vista-20HW Troubleshooting Guide Page 88

  • Download
  • Add to my manuals
  • Print
  • Page
    / 100
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 87
SYMPTOM
1.
Low Batterymessageon
keypad.
2.
Periodic beep(s)from
keypad.
3. Nuisanceor phantomalarm.
4.
Intrusionalarmfornoap-
parentreason.
5. ‘CEJICK” andzonenumber
2-8 isdisplayed.
SYMPTOM
1.
“ACPOWER”light
Off.
z.
Digitalcommunicator mes-
sagenot being received.
3.
Doesnotarmproperly.
4. VISTA-20HW doesn’tre-
spondtokeystrokeson
keypad.
SYSTEM
POSSIBLE CAUSE
la. “Bat”
or “System Lo Bat” (no zone Nos.)
2a. System is in TEST
mode.
3a. Sensors not properly installed, wired, or
monitored.
4a. Protected door or window opened while
system armed.
4b. Improper user operation of exitientry de-
lays.
4c. Magnets located too far from switches,
an~or doors and windows not properly
aligned.
5.
Control has sensed a high resistance
condition on a loop in one of the hard-
wired zones (2-8).
CONTROL
POSSIBLECAUSE
la. Interrupted
AC powersupply.
2a. VLSTA-20HW in TEST mode.
2b. Telephone connection not secure.
2c. Digital communicator malfunctioning.
2d. Telephone number in program needs
prefm or access code.
2e. Telephone call to central monitoring
station requires operator assistance.
3a. Ready light not on. -
4a.
4b.
4C.
M.
“CC” or “MODEM COMM” displayed.
“all” or “System Busy” displayed.
“E4 or “E8”, or “Standby System Busy”
displayed.
Keypad address setting incorrect.
REMEDY
la. System battery is low or missing.
2a. Enter “Code” + OFF to exit TEST mode.
3a. Check installation to see if in accordance
with established procedure.
4a. Check with all occupants of protected
home.
4b. Check setting of entry delay. Exit delay
is 40 seconds longer than the entry delay
time. Remind user of same.
4c. Check all openings for proper switch and
magnet orientation.
5. Check the sensor or the loop wiring in
the affected zone. The system will not
arm until this condition is corrected (or
the affected zone is bypassed).
REMEDY
la. Check transformer connection and
Powerline circuit breaker.
2a. Remove from TEST mode.
2b. Check all connections.
2c. Check with a different VISTA-20HW.
2d. Program prefm or access code into the
VLSTA-20HW.
2e. VISTA-20HW system cannot work in this
situation.
3a. Check for faulted zones and make intact,
I
or use B~ass arming, if desired.
4a.
4b.
4C.
4d.
System is in communication with down-
loader at central station. Wait until
download session is finished.
System has just been powered and is in
its one minute initialization. To bypass
this time, press’# + ‘O’.
More zones have been programmed than
the zone expansion modules can handle.
Keypads must be set for address 31 (non-
addressable mode).
SMOKE DETECTOR
SYMPTOM
I
POSSIBLECAUSE
I
REMEDY
1.
Detectoralarms,noaw
I la. Dust,dirtinsensingchamber.
Ila. Cleanunit’ssensingchamberwith
i
parentreason. -
2.
Detector’ssirensounds.
lb. Improper location.
lc. Unit malfmctioning.
2a. Unit not receiving required power.
vacuum cleaner W;unit’s instructions.
lb. See unit’s instructions for locations to
avoid. Relocate as necessary.
lc. Replace detector.
2a. Check for proper installation of battery.
Try new battery.
2b. Unit malfimctioning. 2b. Replace detector.
I
-88-
Page view 87
1 2 ... 83 84 85 86 87 88 89 90 91 92 93 ... 99 100

Comments to this Manuals

No comments