Programming Options Defined
The following will help you understand the programming of OUTPUT
DEVICES when using *8O and *81 modes. The options used to start and
stop these devices are described below, followed by the actual screen prompts w
and available entries.
The letter(s) in parentheses after each fiction described below, such as (A)
after ACTION, are those that appear in the various summary displays of
programmed data during programming.
ACTION (A) The “ACTION’ of the device is how the device will respond
when it is activated by the “START” programming. You
may want the device to activate momentarily, to pulse on
and off continuously, or to remain activated until some
other event occurs to stop it. There are four different
choices of actions:
ACTIVATE for 2 SECONDS and then reset.
ACTIVATE and REMAIN ACTIYATED until stopped by
some other event.
PULSE ON and OFF until stopped by some other event.
NOT USED when the device is not used.
START (STT) The “START” programming determines when and under
what conditions the device will be activated. The following
START options are available:
A) 1. EVENT (EV) is the condition (Alarm, Fault, Trouble) that
must occur to a zone or group of zones (zone list) in order to
activate the device. These conditions apply
only when a
zone list is used. The different choices for “EVENT” are
listed below and in the “Programming Output Relays &
Powerline Carrier devices” section that follows.
w
ALARM
Relay action begins upon any alarm in
an assigned zone in the zone list.
FAULT
Relay action begins upon any opening or
short in an assigned zone in the zone
list.
c TROUBLE Relay action begins upon any trouble
condition in an assigned zone in the zone
list.
c NOT USED
Relay action is not dependent upon one
of the above events.
2. ZONE LIST (ZL) is a group of zones to which the
“EVENT” applies in order to activate a particular device.
Note that there are a total of 3 zone lists that can be
programmed in field *81 mode; when the selected EVENT
(Alarm, Fault or Trouble) occurs in any zone in the
selected “Start” ZONE LIST (1, 2, or 3), activation of the
selected device will START.
B) 1. ZONE TYPE/SYSTEM OPERATION (ZT). If a System
Operation, such as
“DISARMING” or “ANY FIRE
ALARM,” is to activate the device, the appropriate choice
would also be entered under the “ZONE TYPE” option.
“ZONE TYPE”
is used independently of the
“EVENT/ZONE LIST” combination.
If a specific “ZONE TYFE” is chosen, any zone of that re-
sponse type going into alarm, trouble, or fault will cause the
device to activate as selected in “ACTION.” If the same .,
“ZONE TYPE” is also chosen for the STOP programming,
any zone of that type that restores will de-activate the
device.