ZONE ASSIGNMENT/ALARM REPORT CODES
REFER TO THE ZONE ASSIGNMENT T)4.BLE FOR *56 IN THE
CENTERFOLD PROGRAMMING FORM .
This is an interactive menu mode that is used to program zone
numbers, zone types, partition numbers, alarm and report codes, and
to identify the type of loop input device. This mode can also be used
for entering Alpha descriptors for zones (we recommend entering
descriptors in menu mode *82.
Upon entry menu mode *56, the following is displayed:
Zone Number (Zn): Enter the zone number that you wish to
program (or [0][0] to leave zone programming).
Press [*]. A summary display will come up, showing the status of that
zone’s program.
If it is programmed satisfactorily, press [#] to back up one step and
enter another zone number, if desired.
If the zone is not programmed, or you want to change it, press [*]. A
prompt for Zone Type will appear.
J ZoneNumber
m listedbelOw
Zone Type (ZT): Each zone must be assigned to a zone type, which
defines the way in which the system responds to faults in that zone.
Enter the zone type code (or change it, if necessary). Zone types are
00= NotUsed
06= 24 Hr Silent
10. Interiorw/Delay
01 = Entry/Exit#1
07= 24 HrAudible
23. No Alarm
02= Entry/.Exit#2 08=24 HrAux
Response
03 = Perimeter
09= FireW/venf.
24= SilentBurglary
04= interiorFollower
05= TroubleDay/AlarmNight
Default values for zones 01 to 08 are:
Zone No.(Zn): 01
02
03 04 05 06
07 08
Zone Type Default 09 01
03 03 03 03 03 03
Partition Default
1 1
1 1 1 1
1 1
Response Time
Default *
1 1
1 1 1 1
1 1
x ulflfor response time
= 350 msec.
I
17
Partition
1
I
When the display shows the zone type you want, press [*I to advance
to...
Partition No. (P) (Default = [1].
Enter”1” or “2”.
Press [*] to advance to...
Report Code (RC): The report code consists of 2 hexadecimal digits,
each in turn consisting of 2 numerical digits. For example, for a report
code of “3C”, enter [0][3] for “3” and [1][2] for “C”.
Enter the numbers and press [*] to advance to...
Input Device (In): For the hardwired zones of the VISZ’A-20HW
(HW), the auxiliary wired expansion zones on a 4219 or 4229 (AW),
the Input Device types are automatically displayed (Panic, Duress,
and Tamper inputs are not applicable).
When all is okay, press [*] to advance to...