Enter the partition to which this zone is
assigned, “l” or “2”. The factory default is
partition 1. Press [*] to continue.
-1 for1~ad[l][2]f0rC. Re~er~oSectio7z15
The report code consists of 2 hexadecimal digits,
each in turn consisting of 2 numerical digits. For
example, for a report code of 3C , enter [0][3]
SYSTEM COMMUNICATION for complete
information on report codes, if necessary.
Enter the desired report code and then press [*I
to continue.
‘1 ~~~~fRj~5e~on.10msec,u~
Enter the desired response time for the zone.
Press [*] ;o continue.
Typicalsummarydisplay
-l Con,ue
A summary display will appear, showing the
data for the zone that was just programmed.
If It M programmed satisfactorily, press [*] to
ml
The next request is to enter Alpha descriptors
for the zones. The entry may be done now (enter
1) or may be done at a later time using X82
interactive mode (enter O).We recommend that
the entry of Alpha descriptors be done using *2
mode.
See Section
14. ALPHA DESCRIPTION
PROGRAMMING for specific procedure
-zoneas.icatedPre.o.slY.
If “0” (no) was entered above, the system will
return to the Enter Zone Number prompt.
Proceed with the programming for the next
Whe~ you have programmed all the hard-wired
zones satisfactorily, exit *56 interactive mode at
the Enter Zn Num. prompt by pressing [01[01*
Then exit the programming mode by keying *99.
Proceed to the check-out procedure that follows.