ADEMCO Vista-20HW Troubleshooting Guide Page 91

  • Download
  • Add to my manuals
  • Print
  • Page
    / 100
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 90
specifications
V-ISTA-20HW
1. Physicak 12-W” W x 14-1/2° H x 3“D (318mm x 368mm x 76mm).
SECURITY CONTROL
2. Electrical
VOLTAGE INPUT: 16.5VAC from plug-in 25VA transformer, Ademco No.
1321/TF2 (in U.S.A.).
RECHARGEABLE BACK- UP BATTERY: 12VDC, 4AH (Gel type)
minimum. Charging Voltage: 13.8VDC.
ALARM SOUNDER: 12V, 2.o Amp output can drive 12V BELLS or can
drive one or two 702 (series connected) self-contained 20-watt sirens. Do
not connect two 702s in parallel.
AUXILIARY POWER OUTPUT: 12VDC, 600mA max. Interrupts for 4-
wire smoke detector reset.
Note: For UL installations, Alarm Sounder plus Auxiliary Power currents
should not exceed 700mA total.
STANDBY TIME: (see formula in Section 13. FINfi POWER UP for
required battery size needed).
FUSE: Battery (3A) No. 90-12.
3. Communication:
FORMATS SUPPORTED:
Ademco Express,
10 charactershec,DTMF (TouchTone)DataTones,1400/2300Hz ACK,
1400Hz KISSOFF.
Ademco Contact ID Reporting,
10 characters/see.,DTMF (TouchTone)DataTones,1400/2300Hz ACK,
1400Hz KISSOFF.
Ademco Low Speed, 10 pulses/see,1900HzDataTone,
1400Hz ACWKISSOFF.
Radionics/SESCOA 20 pulseshec,1800HzData Tone, 2300Hz
ACWKISSOFF. Can report O-9, B-F
Line Seize: Double Pole.
Ringer Equivalence: 0.7B.
FCC Registration No.: AC 398U-68192-AL-E.
4. Maximum Zone Resistance: Zones 1-8= 300 ohms excluding EOLR
4127
1. Physicak 5-5/8” W x 4-11/16 H x 7/8” D (143mm x l19mm x 22mm).
REMOTE KEYPAD
2. Electrical: Voltage Input: 12VDC, Current Drain: 20mA.
3. Interface Wiring Tocontrolpanel’skeypadconnectionpoints.
RED:
12VDCinput(+) auxpwr.
GREEN: Data Outto Control.
YELLOW: DataInhornControl.
BLACK Ground.
4137AD & 5137AD
1. Physicak
8-2/5” W x 4-3/4’ H x 1-1/10”D (213mmx 121mmx 28mm).
REMOTE KEYPADS
2. Electrical VoltageInput: 12VDC.
Current Drain: 60mA (4137A.D).
9onA(5137AD).
3. Interface Wiring
RED:
BLUE:
GREEN:
YELLOW
BLACK
12VDC input (+) auxiliary power.
18VDC input from optional No 1350 or 1360 Power Pack
(not usable for UL installations).
Data Out to Control.
Data In from Control.
Ground (–) connection horn optional No. 1350/1360 Power pack.
-91-
Page view 90
1 2 ... 86 87 88 89 90 91 92 93 94 95 96 ... 99 100

Comments to this Manuals

No comments