The VISTA-20HW is a 2-partition control that supports up to 16 zones
using basic hard-wired and wired expansion zones, plus 3 keypad zones.
Baeic Hardwired Zones (8)
Provides 8 basic hardwired zones having the following characteristics:
EOLR supervision supporting N.O. or N.C. sensors
Programmable response time (10, 350, or 700 milliseconds)
Individually assignable to either partition
Up to sixteen 2-wire smoke detectors on zone 1
4-wire smoke or heat detectors on zones 2 through 7 (as many as can be
powered fkom AUX power on the control)
Up to fi~ 2-wire latching type glassbreak detectors on zone 8 with auto
reset
optional
Wwed Expansion zones (up to 8)
Supports up to 8 additional wired zones using a 4219 expansion module or
4229 expansionhelay module. These zones have the following
characteristics:
Two partitions
EOLR supervision supporting N.O. or N.C. sensors
300-500 msec normal response with an option for fast (10-15 msec) re-
sponse on loop A (fist expansion zone)
Provides the ability to control two separate areas independently, each
area functioning as if it had its own separate control (each with its own
Master code and user codes, as programmed)
Zones assignable to either partition 1 or 2
Relay and Powerline Carrier device outputs assignable to either
partition 1 or 2, or to both partitions
Certain m’o!narnmed svstem oDtions. such as Entrv/Exit delav and
Subscriber Account n~mber, ~rogrammed indepe~dently for- each
partition
Remote Keypads
Up to 4 of any of the following keypads may be used in each partition:
Fixed-Word Keypads:
4127*, 4137AD, 6127*, 6137, and 6128.
* These keypads cannot be used if the 4285 VIP (VISTA Interactive Phone)
Moduleis beingused.
AZphaKeypads: 5137AD, 6139 (2-line alphanumeric displays)
6138 (l-line alphanumeric display).
Security Codes
One installer code for entire system (user 1)
One Master code for each partition (user 2)
12 secondary user codes for each partition (users 3-14)
One baby-sitter code for each partition (user 15)
c One duress code for each partition (user 16)
-9-