Programming Output Relays and Powerline Carrier Devices
1. With at least one 2-line Alpha keypad (5137AD or 6139) connected to the
Partition 1 keypad terminals on the control, power up the system
temporarily. If you had previously connected the AC transformer to the
control panel, you need only plug in the transformer (to 120VAC outlet) to
power up the system.
2. Enter the programming mode by keying the following on the Alpha
keypad: Installer code (41 12) +8+ O+ O.
3. Press *7. POWERLINE CARRIER DEVICE HOUSE ID.
Enter House ID 1-15 for Powerline Carrier devices, as follows:
0= A,l=B,2= C,3=D,4= E,5=F,6=G,7 =H,8=I,9=J,#+ 1O=I-$
#+ll=L, #+12= M,#+13=N, #+ 14=0, #+15=P.
Default is O.
The House ID must match the House ID set on the powerline carrier
devices. The unit ID for these devices is 1-8 depending on which device is
being programmed. For example, device #1 must be set to unit ID 01,
device #2 to unit ID 02, etc.
4. Press *80. Note that this is an interactive programming mode. It is
used to program all output devices used in the system (4229 or 4204
Relay modules, or Powerline Carrier devices). Refer to the Programming
Form worksheet for *8O Interactive Mode.
OutputDeviceDisplays ~
~,
Upon pressing *80, this screen will appear. Enter the Device Number 01 or
02 for a 4229, or 01, 02, 03, or 04 for a 4204, or 01-08 for Powerline Carrier
01 devices (or 00 to end these entries). Press the [*I key to continue.
The [*] key is used to accept an entry and advance to the next prompt. The
[#] key is used to revert back to the last question to check or change an
entry. Press [*] to go forward again.
lKT?zq
This screen displays a stimary of the current Device START programming
(for this example, device 02 has been selected).
Press the [*] key to continue.
~
This screen displays a summary of the current Device STOP programming.
I
02 AEVZLZT P
STP - -0001
II
m
II
02 StarE
Zn List
No List o
II
II
02 Start:
Zn
Typ
Not Used
00
II
Press the [*] key to continue.
Enter the desired device action as listed below. Press the [*] key to continue.
O= No response 2 = Close and Stay Closed
1 = Close for 2 seconds 3 = Continuous Pulse on & off (1 sec ON, 1 sec OFF)
Enter the event to START the relay
O= Not used 2 = Fault; 1 = Alarm; 3 = Trouble
A zone list must be used in conjunction with an event. If a zone type/system
operation is to be used instead of an event, enter O.
Press the [*] key to continue.
If a zone list will be used to START the relay action, enter the zone list
number (to be programmed in field *81): 1, 2, or 3. If not used, enter O.Press
the [*] key to continue.
If a zone type or system operation will be used to START the device action,
enter the appropriate two-digit code (see table that follows). If not, enter 00.
Press the [*] key to continue.