DIALER
PROGRAMMING
(--50)
Fields *40, WI, W:
Enter up to the
number of digits
shown. Do not fill
unused spaces.
Enter O-9,
# + 11 for ‘*’
# + 12 for ‘#’
# + 13 for a pause
(2.5 sees)
*36
*37
*38
*4O
*41
*44
*45
AUDIBLE EXtT WARNING
Partition1
❑
Partition2 ❑
If enabled, this field provides exit warning sound when armed AWAY
it can be selected for either or both Partitions.
Warning sound consists of slow continuous beeps until last 5 seconds,
when it changes to fast beeps. The warning sound will end at the
termination of Exit time. O= no; 1 = yes. Default is 1.
CONFIRMATION OF ARMING DING Part’n1
❑ Part>n2 ❑
Enter 1 (in either or both Partitions) to enable 1/2 second external
alarm sounding “ding” when closing report goes in, or at the end of exit
delay. Odisables the “ding” (default).
POWER UP IN PREVIOUS STATE
•1
Enter 1 for Yes (default) if, upon power-up, you want the system to
assume the system status prior to power down. Enter Oif you want the
system to always power up in a disarmed state.
When the system powers up armed, an alarm will occur 1 minute after
arming if a zone is faulted. Must be 1 for UL applications.
Note that if the previous state was armed AWAY or STAY, the system
will not respond to sensor changes for 1 minute, which allows time for
sensors such as PIRs to stabilize.
PABX ACCESS CODE (See Box at Left)
~
Enter up to 4 digits if PABX is needed to access an outside line. If
fewer than 4 digits are needed to be entered, exit by pressing * and
next field number (e.g., 41). To clear entries horn field, press =0*.
PRIMARY PHONE No. (See Box at Left)
11111111111
Enter up to 12 digits.
If fewer than 12 digits entered, exit by pressing * and next field
number (e.g., 42). To clear entries fkom field, press *41*.
Note: Back-up reporting (8 calls are made to the secondary phone
number if no kiss-off is received after 8 attempts to the primary
number) is automatic only if there is a secondary phone number (field
*42).
SECONDARY PHONE No. (See Box at Left)
11111111111 Enter up to 12 digits.
If fewer than 12 digits entered, exit by pressing * and next field
number (e.g., 43). To clear entries from field, press *42*. See Note
in field *41 above, also.
Notes For Fields W, W, W, and *6.
Entries providedfor up to 4 digitsfor primary office and 4 digits for
secondary.
Enter digits O-9; # +ll=B; # +12=C; # +13=D; # +14=E; or # +15=F.
Enter *as the fourth digit if a 3-digit account number (for 3+1 dialer
reporting format) is used. Enter Oas the first digit of a 4-digit account
number for Nos. 0000-0999. Exit field by pressing * (and press next
field number) if only 3 digits are used.
To clear entries from field, press *3*, W*, *45* or *46*.
See blank Programming Form for examples of Account No. entries.
PRIMARY SUBSCRIBER ACCOUNT. No. (partition1)
~
Primary Receiver.
See notes above.
SECONDARY SUBS ACCOUNT. No. (partition 1)
~
Secondary Receiver.
See notes above.
PRIMARY SUBSCRIBER ACCOUNT.. No. (Partition 2)
Ill
I Primary
Receiver.
See notes above.
-73-