1. With at least one 2-line Alpha keypad (5137AD or 6139) connected to the
Partition 1 keypad terminals on the control, power up the system
temporarily. If you had previously connected the AC transformer to the
control panel, you need only plug in the transformer (to 120VAC outlet) to
power up the system.
2. Enter the programming mode by keying the following on the Alpha
keypad Installer code (41 12) + 8 + O+ O.
Note that it is not possible to enter the programming mode if Partition 2
is in an armed state.
3. Press *56. Note that this is an interactive programming mode. You will
use it to program zone numbers, zone types, partition numbers, alarm
report codes, and to program response times for hard-wired zones.
II
Enter Zn Num.
(00 = Quit)
01
II
‘Ilmicalsummarydimlay
J.Zone Number
II
02 Zone Type
Perimeter
03
II
ZoneType ~
Upon entering *56 mode, this prompt will be
displayed. Enter the first zone number that
you wish to program (or [0][0] to exit zone
programming). If you are starting with zone 2,
enter “02”. Press * to continue.
A summary display will appear, showing the
present status of that zone’s programming.
Zn = zone number;
ZT = zone type;
P = partition to which zone is assigned;
RC = report code for that zone;
In= input type of zone;
RT = response time for that zone.
Values displayed are currently programmed
values.
If it is programmed satisfactorily, press [#] to
back up one step and enter the next zone
number, if desired.
If you want to change a zone’s programming,
press [*]. A prompt for Zone Type will appear.
Each zone must be assigned a zone type, which
defines the way in which the system responds
to faults in that zone. A detailed explanation of
each zone type is provided in “Response Type
Definitions” in Section 16. ZONE RESPONSE
TYPE DEFINITIONS.
Enter the desired
below.
00. ZoneNot Used
01= Entry/Exit#1
02= Entry/Exit#2
03= Perimeter
04= InteriorFollower
zone type code, as listed
07= 24 Hr Audible
08.24 Hr Aux
09= Fire (W/verif.)*
10= Interiorw/Delay
23= No Alarm
05. TroubleDay/AlarmNight
Response
06= 24 HrSilent
24= SilentBurglary
* The verification” featureis only activewhen zone
type 09 is assignedto hard-wiredzone 1.
When the display shows the zone type you want,
Dress [*1 to continue.
-24-