I
07 Response Time
1
II
Typicalsummarydisplay
m
I
Program Alpha?
O= Nol= Yes O
I
Enter the desired response time for zone 7.
The recommended entry for keyswitch
operation is “1” (the factory default).
Selections available are: “0” (10 msec), “1” (350
msec), or “2” (700 msec).
Enter the desired numbers and then press [*I
to continue.
A summary display will appear, showing the
data for zone 7 that was just programmed.
If it is programmed satisfactorily, press [*I to
continue.
The next request is to enter an Alpha
descriptor for zone 7. Since this is a
keyswitch zone, no descriptor is required.
Enter “O”.
If “O” (no) was entered above, the system will
display a prompt for entry of the number for
the next zone.
Press [01[01 plus [*I to exit *56 mode.
Exit the progr
arnrning mode by keying *99.
After keyswitch operation is verified (see
below), unplug the AC transformer.
KeysWitch Operation
To arm AWAY, turn key and release within a 1/2 second. To arm STAY,
turn and hold key for longer than 2 seconds. To disarm, turn key and
immediately release.
LED indications are defined as follows:
GREEN
RED
MEANING
OFF
OFF
DISARMED& NOT READY
ON
OFF
DISARMED& READY
OFF
ONSTEADY
ARMEDAWAY
OFF
SLOWFLASH
ARMEDSTAY
OFF
RAPIDFLASH
ALARMMEMORY