Descriptions of System Data Fields
THEBLANKPROGRAMMINGFORMSHOULDBEUSEDTORECORDTHEDATAFORTHISINSTALLATION
Defaults (where applicable) Are Indicated In Text
The following is a table containing a list of all data fields in this control
(presented in numerical order). If you have performed the programming
instructions that were included with the installation of each of the various
peripheral devices covered in previous sections, this table will simply serve as
a reference for all data fields in the system. If you have decided to program
all the data fields in the system at one time (and therefore did not perform
the programming indicated previously in each section), you can use this table
to program all the data fields now.
*2O
*21
*23
*25
*27
*X3
INSTALLER CODE
lJJJ_l
The Installer code is used to enter the 4digit Master security code
for each partition in the normal operation mode, via the keypad
connected to Partition 1. See “Master Code” in Section 20. SYSTEM
OPERATION for procedure.
Enter 4 digits, O-9. Default is 4-1-1-2,
QUICK ARM ENABLE
Partition1
Partition2
If enabled, the [#] key can be used instead of the security code when
arming the system.
Enter Ofor disabled or 1 for enabled for each partition. Default is O.
FORCED BYPASS FUNCTION Partition1
Partition2
This feature allows sll faulted zones to be bypassed automatically.
All zones that are bypassed by this fimction will be displayed after
the bypass is initiated. Enter, for each partition:
O= No forced bypass. This is the default.
1 = Allows automatic bypass of all open zones.
Must be “O” for UL installations.
I
WIRED ZONE EXPANSION
u
Use this field to select the type of expansion unit being used, as
follows
O= none; 1 = 4219; 2 = 4229; 3 = 4204. Default is O.
POWERLINE CARRIER DEVICE (X-1O)HOUSE ID
Powerline Carrier devices require a House ID. This field identifies
this house ID to the control.
If Powerline Carrier devices are used, they are selected in field * 80.
House ID is entered in following manner:
0= A,1=B,2=C, 3= D,4=E,5=F, 6= G,7=H,8=I,9=J,
#+10= ~#+ll=L, #+12= M,#+ 13= N,#+14=0, #+15=P.
Default is O.
VOICE MODULE PHONE CODE (4285)
m
The use of a 4285 VIP Module (can be used in Partition 1 only)
requires a 2-digit code.
Enter a 2-digit phone access code as follows: For first digit, enter
any any digit from 1 to 9; for second digit, enter # +11 for “*”, or
# +12 for “#”.
Exomple: If desired access code is 7*, 7 is the first entry, and # + 11
(for *) is the second entry.
Default is “00” (Voice Module disabled). Note: A “O” in either digit
will disable the Voice Module.