ADEMCO Vista-20HW Troubleshooting Guide Page 78

  • Download
  • Add to my manuals
  • Print
  • Page
    / 100
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 77
RESTORE
*69
REPORTCODES
(*6=76)
*7O
*71
*72
*73
*74
*75
*76
*8O
*81
*8,2
GROUP RESTORES FOR TROUBLE, BYPASS
EnterO for no (report for ~ restore), or 1 for yes (report after M
zones restored). Default is “O”. Note: 1“ not applicable to Contact
ID reporting.
~,
ALARM RESTORE REPORT CODE, 1st DIGIT
•1
2nd digit is automatically sent as the 2nd digit of the zone alarm
report code programmed in field *56, if expanded or 4+2 reporting is
selected.
TROUBLE RESTORE REPORT CODE
m
See box on previous page. This is sent when a trouble in a zone is
restored. Field *69 applies.
BYPASS RESTORE REPORT CODE
m
See box on previous page. This is sent when a zone that has been
bypassed is un-bypassed. Field *69 applies.
AC RESTORE REPORT CODE
m
Seeboxon previouspage. Reports with Partition 1 Subscriber No.
LOW BAT RESTORE REPORT CODE
m
Seeboxon previouspage. Reports with Partition 1 Subscriber No.
RF XMTR LOW BAT RESTORE REPORT CODE.
(NOT USED)
TEST RESTORE REPORT CODE
m
See boxon previouspage. Reports with Partition 1 Subscriber No. A
restore code entered here will cause a restore message to be sent
when Test mode is exited.
OUTPUT DEVICES
This is an interactive menu mode that is applicable only if field *25 is w
programmed for a 4229 or 4204, or if Powerline Carrier devices are to
be used. See Section 7. REL4Y OUTPUTS & POWERLINE CARRIER
DEVICES for a detailed programming procedure. Also refer to the
OUTPUT DEVICE table for *8O in the Programming Form.
ZONE LISTS FOR OUTPUT DEVICES
This is an interactive menu mode that is applicable only if field *25 is
programmed for a 4229, 4204, or if Powerline Carrier devices are
used.
Refer to Section 7. RELAY OUTPUTS & POWERLINE CARRIER
DEVICES for a detailed programming procedure. Also refer to the
ZONE LISTS FOR OUTPUT DEVICES table for *81 in the
Programming Form.
CUSTOM ALPHA EDITING
See Section 14. ALPHA DESCRIPTION PROGRAMMING for
procedure.
DDDELETE RF INPUT IDs. (NOT USED)
EVENT LOG 80% FULL REPORT CODE
m
(Also see “To PROCRAM SYSTEM STATUS, & RESTORE REPORT
CODES box on a previous page).
If an Event Logging selection is made in field *90, a message can be
sent to the central station receiver when the log is 80% full. If the log
becomes fill, a new message will overwrite the oldest message in the
log.
Note: Aside from the selection made by the installer in field *90, all
control and readout from the log is accomplished via the Downloader
(see field *90).
-76-
Page view 77
1 2 ... 73 74 75 76 77 78 79 80 81 82 83 ... 99 100

Comments to this Manuals