ADEMCO Vista-20HW Troubleshooting Guide Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 100
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
4285 Module WIMg
The 4285 is wired between the control panel and the premises handset(s). It
listens for touch tones on the phone line and reports them to the control
panel. During on-premises phone access, it powers the premises phones; WI
during off-premises phone access, it seizes the line from the premises phones
and any answering machines.
Note: The phone lines must be in service for the 4285 module to function,
even when accessing the system from an on-premises phone.
1. Make 12V (+) and (–) and data in and data out comections from the 4285
module to the control, using the connector cable supplied with the 4285
(see Figure 16).
~
*
These are the same connections
as those usedfor remotekeypads
connectedto Partition1.
\ YELLOW I DATAOUT(terminal7) ~
2. Insert the keyed connector at the other end of the connector cable into the
4285 WIRING TABLE
I
4285Terminal I COMeCtStO:
I
1. PhoneIn (Tip)
Terminal(23)on control.
2. PhoneIn (Ring)
Termiml (24)on control.
3. PhoneOut(Tip)
BROWNleadfromdirect-connectcord.
4. PhoneOut(Ring)
GRAYleadfromdirect-connectcord.
5. Ground
Earthgroundterminal(25)on control.
r—
6.Not Used
7.Not Used
Caller ID Units
If the telephone system on the premises includes a Caller ID unit, connect the
Caller ID unit directly to the “Handset” terminals (21 &22) on the control as
shown in 4285 Wiring Connections diagram that follows.