This section provides information on how programming is performed in this
system. It will enable you to understand how to enter and exit the
programming mode, and how to program the data fields and the user-friendly
interactive modes (*56, *80, *81, *82, *83). We therefore urge you to read
and understand the following before proceeding with the installation.
I
General Programming
Information
Characteristics for each installation are stored in non-removable, electrically
erasable, non-volatile EEROM memory. These must be programmed for the
particular installation to establish its specific alarm and reporting features.
It is possible to program the system at any time, even at the installer’s
premises prior to the actual installation. Simply apply power temporarily to
the control and then program the unit as desired.
Important Note: You cannot enter the programming mode unless
- partitions are disarmed.
There are two programming modes: data field programming and interactive
(menu) mode programming. Data field programming is used for setting
various system options and interactive programming is used for
programming zone information, programming relay outputs, and for learning
transmitter serial numbers.
.
::,:,
Programming can also be performed remotely from the installer’s officelhome,
using an IBM personal computer, a modem, and V-Link downloading
software. See the Section 18. REMOTE PROGRAMMING AND CONTROL
(DOWNLOADING).
Entering Program Mode
You may use one of the following methods:
a) Press both the [*I and [#] keys at the same time within 50 seconds
after power is applied to the Control, or
b) Mter power up, enter the Installer code (4 1 1 2)+8 O 0.
This method is disabled if you exit the program mode using *98 instead of
*99. See
“Exiting Program Mode” par~aph later in this section.
If a diHerent Installer code is subsequently programmed, use it instead of
4112 to gain access to the Programming
g mode.
Following entry into program mode, data field *2O will be displayed (this is
the first field in the system). The system will now accept entries for field =0.
1.
2.
Data F5ekl
Press[*I plus Field No. (for example, *21), then make the required entry.
When you have completely programmed a data field, the keypad will
“beep” three times and then automatically display the next data field in
sequence. Togo to a different field, press [*] plus the desired field No.