*W EVENT LOGGING
The VISTA-20HW system has the ability to record various events in a
history log (48-event capacity). The types of events to be logged can be
selected as indicated below. At any time, the downloader operator can
then upload the log and view or print out all or selected categories of
the log. The log can also be cleared by the downloader operator.
The display/printout at the central station will show the date, time,
event, and description of the occurrences. The time is calculated by an
internal clock at the central station computer. Note that the time for
any events that occur prior to a system power-down or an entry into
the programming mode cannot be calculated by the central station
computer. The time will then appear on the log as “unknown”.
O= None; 1 = Alarm/Alarm Restore; 2 = ‘l?roublal’rouble Restore;
4 = Bypass/Bypass Restore; 8 = Open/Close. The default is “3”.
Example: To select “Alarm/Alarm Restore”, and “Open/Close”, enter
9(1 + 8); to select all, enter #15.
Note: System messages are logged when any non-zero selection is
made.
*9 I OPTION SELECTION
Enter “4” if an Audio Alarm Verification (AAV) unit is connected in the
system (l-3 not used); enter “O”if an AAV unit is not being used.
For UL installations, the AAV option must be disabled (enter
“o”).
I
*92 PHONE LINE MONITOR ENABLE
u
O= Notused(default)
1 = Localkeypaddisplayonlywhenphonelineis faulted.
2 = Localkeypaddisplaypluskeypadtroublesoundwhenlineis faulted.
Eachpartitionturns offits owntroublesound.No automatictimeout.
3 = Same as “2” aboveplus DeviceNo. 2 STARTS. If eitherpartitionis
armed,externalsounderactivates.External sounderwill be turned
offby normalbell timeout,orby securitycodeplus OFF from either
partition (it does not have to be the one that was armed).
Device number 2 must either be programmed to be STOPPED in
field *8O or STOPPED by entry of security code + # + 8 + 2.
Ptiition in *8O should be set to “O“for STOP.
NOTE: Option 3 may be used even if a relay unit or Powerline
carrier device is not connected to the control.
I
*93 ~ER C)I?REPORTS IN ARMED PERIOD
u
This option can be used to limit the number of messages (alarm& alarm
restore reports) sent to the central station in an armed period. “O”
limits reports to a total of 10; “1” allows an unlimited number of
reports. Default is O.
DOWNLOAD
*W DO~OAD PHONE NUMBER
INFORMATION
Enterup to 12 digits;
(*9.4, *95)
11111111111
0-9. #
+11 for “*”. # + 12 for “#”, # + 13 for a pause. Do not fill unused
spaces. End field by entering*. “Toclear entri~s from field, press *9LM.
*95 RING DETEC~OIN COUNT FOR DOWNLOADING
u
Enternumberofrings beforecontrolpicksup phoneline(orOor 15).
Refertothe chartthat followsandprogram
this field accordingly.
-79-